This test is most useful if any of these apply to you.
Penicillium notatum IgG can help identify a possible mold exposure during an investigation of unexplained lung inflammation. Its clearest clinical role is in the evaluation of hypersensitivity pneumonitis. A positive result supports previous immune contact with the mold or a related organism, but doesn't establish how much you encountered, where the exposure happened, or whether it caused your symptoms.
This is a specialized supporting marker with limited standardization. Its use in general health screening, routine monitoring after mold cleanup, and diagnosis of eye or nasal allergies remains unvalidated.
Antibodies are proteins your immune system makes to recognize particular substances. IgG stands for immunoglobulin G. Mold-specific IgG can develop after exposure, including in people who remain healthy. IgE is a different antibody class involved in immediate allergic reactions.
The test measures mold-binding IgG in serum obtained from a blood draw, using a fluorescence enzyme immunoassay. Serum is the liquid left after blood clots. The assay measures antibody binding to a mold extract, so the result reflects your immune response rather than the amount of mold in your body or building.
Clinical laboratories use Penicillium notatum and Penicillium chrysogenum as alternate names for this test's mold target. These molds occur in indoor environments and on food. The antibody result cannot distinguish between different sources of exposure.
Hypersensitivity pneumonitis is inflammation of the lungs caused by an immune response to inhaled substances. Mold is one possible trigger. The disease can cause cough and breathlessness, and some forms lead to lung scarring.
A documented occupational case involved an onion and potato sorter with work-related breathing symptoms. Researchers detected serum IgG against Penicillium species and Fusarium solani cultured from the workplace. The antibodies also reacted across several Penicillium species and with Aspergillus fumigatus. This was evidence involving workplace-specific extracts and several organisms, not a validation study of this single clinical assay.
Studies combined in a 2020 guideline measured serum antibodies against various possible triggers using several laboratory methods. The tests identified about 83 of every 100 people with hypersensitivity pneumonitis, while also testing positive in about 32 of every 100 people with other interstitial lung diseases. Those figures describe broader antibody testing and cannot be assigned to Penicillium notatum IgG alone.
Diagnosis depends on how the exposure history fits chest imaging and, when needed, findings from lung-fluid sampling or tissue examination. A positive antibody result can help focus the exposure investigation. A negative result cannot exclude the disease.
An exploratory study compared 40 people with year-round allergic conjunctivitis with 20 healthy controls. It used a research ELISA to measure serum antibodies against Penicillium extracts. This was a different assay from the fluorescence-based clinical method, so its numerical results aren't interchangeable with your result.
The paper reported positive Penicillium IgG results in 30% of the allergy group and 5% of controls. It also reported associations with skin-prick reactions and eye-disease severity. However, the comparison of antibody levels between the groups was not statistically significant, despite broader claims in the abstract. The study was small and cross-sectional, and it did not establish that adding this clinical test improves diagnosis, treatment selection, or monitoring.
A separate study of people with symptoms attributed to a damp building found no difference from controls in serum IgG against Penicillium expansum. That is a related species measured with a research assay, so the finding is indirect evidence for this test. It does show why results from different molds and methods need to be kept separate.
The range of molds in a building also matters. A survey published in 2022 found that Penicillium was the predominant cultured mold group in air samples from water-damaged homes, with average counts about three times those of Aspergillus. At the time of the study, none of the five predominant Penicillium species identified was available as a clinical testing extract. This environmental study explains a limitation of mold-test coverage; it did not measure this blood test's accuracy.
Mold-specific IgG may decline after exposure ends, but it can remain elevated after successful treatment or exposure avoidance. Studies and specialist guidance on hypersensitivity pneumonitis do not support using persistent IgG alone to identify ongoing exposure. A change in this result has no validated interpretation as a measure of how well a home was cleaned or how much your lungs have recovered.
Penicillium Notatum IgG is best interpreted alongside these tests.